Remote Link Help

XT75

The following table columns are arranged to follow the typical panel programming order and values required for each item. For example, you should first program a wireless keypad in Device Setup, where you give it a device number, select a device type, select a device communication type, then enter the wireless serial number before programming other options. For additional installation requirements and programming options, refer to the model's installation guide.

  • Models: The accessory item's model number and name, linked to its installation guide.

  • Program In: The menu where you program the accessory: Device Setup, Zone Information, Output Information, or Key Fobs.

  • Device, Zone, or Output Number: The range of numbers for the accessory, depending on where it is programmed. See above. Keep in mind that although any device can be programmed as device 1 in the panel, that address should be reserved for the primary system keypad in most cases.

  • Device Type: If the accessory is programmed in Device Setup, this lists possible device types.

  • Device Communication Type: If the accessory is programmed in Device Setup, this lists possible communication types.

  • Zone Type: If the accessory is programmed in Zone Information, this lists possible zone types.

  • Wireless SN Range: For a wireless device, the typical serial number range of its class.

Models

Program In

XT75 Device, Zone, or Output Number

Device Type

Device Communication Type

Zone Type

Wireless SN Range

714/715 Zone Expansion Module

Device Setup

1-8

EXP

n/a

n/a

n/a

714-8/714-16 and 714-16/715-16 Zone Expansion Modules

Device Setup

1-8

EXP

n/a

n/a

n/a

714N-POE Zone Expander Module

Device Setup

1-8

EXP and NET

NET

n/a

n/a

734 Access Control Module

Device Setup

1-8

DOOR

KPD

n/a

n/a

734B BIN Access Control Module

Device Setup

1-8

DOOR

KPD

n/a

n/a

734N/734N-POE Network Access Control Module

Device Setup

1-8

DOOR

KPD

n/a

n/a

7000 Series Thinline Keypads

Device Setup

1-8

KPD or DOOR

KPD

n/a

n/a

7300 Series Icon Keypads

Device Setup

1-8

KPD

KPD

n/a

n/a

7463 Network Thinline Keypads

Device Setup

1-8

KPD

NET

n/a

n/a

7800 Series Graphic Touchscreen Keypad

Device Setup

1-8

KPD

NET

n/a

n/a

1100R Repeater

Zone Information

Consecutive if more than one per panel: 500-599

AUX1

n/a

AUX1

13000000-13999999

1100T Wireless Translator

Device Setup

2-8

1100T

n/a

n/a

13000000-13999999

1100T Wireless Translator

Zone Information

500-599

n/a

n/a

Any

Non-DMP SN

1101 Universal Transmitter

Zone Information

500-599

n/a

n/a

Any

01000000- 01999999

1102 Universal Transmitter, external contact

Zone Information

500-599

n/a

n/a

Any

01000000- 01999999

1103 Universal Transmitter

Zone Information

Consecutive: 500-599

n/a

n/a

Any

01000000- 01999999

1106 Universal Transmitter, internal/ external contact

Zone Information

500-599

n/a

n/a

Any

01000000- 01999999

1107 Micro Window Transmitter

Zone Information

500-599

n/a

n/a

NT

02000000- 02999999

1108 Doorbell Module

Zone Information

500-599

n/a

n/a

DB

02000000- 02999999

1114 Four-Zone Expander Module

Zone Information

Consecutive: 500-599

n/a

n/a

Any

08000000- 08999999

1115 Temperature Sensor and Flood Detector

Zone Information

500-

n/a

n/a

SV

08000000- 08999999

1116 Relay Output

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15100000- 15199999

1117 LED Annunciator

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15100000- 15199999

1118 Remote Indicator Light

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15100000- 15199999

1119 Door Sounder

Zone Information

500-999

n/a

n/a

NT or DY

02000000- 02999999

1119 Door Sounder (Output)

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15100000-15199999

1122 PIR

Zone Information

500-599

n/a

n/a

NT

09500000- 09999999

1126R Ceiling Mount PIR

Zone Information

500-599

n/a

n/a

NT

09100000- 09499999

1127 Wall Mount Curtain PIR

Zone Information

500-599

n/a

n/a

NT

09100000- 09499999

1128 Glassbreak

Zone Information

500-599

n/a

n/a

NT

03000000- 03999999

1131 Recessed Contact

Zone Information

500-599

n/a

n/a

Any

02000000- 02999999

1134 Access Control Module

Device Setup

1-8

DOOR

n/a

WLS

14300000- 14499999

1135 Siren

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15200000- 15999999

1136 Remote Chime

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15200000- 15999999

1137 LED Emergency Light

Output Information

450-474 (slow); 480- 499 (fast)

n/a

n/a

n/a

15200000- 15999999

1139 Bill Trap

Zone Information

500-599

n/a

n/a

PN

02000000- 02999999

1141 Wall Button

Zone Information

500-599

n/a

n/a

Any

04000000- 04999999

1142 Two-button HoldUp

Zone Information

500-599

n/a

n/a

PN

04000000- 04999999

1144 Key Fob

Key Fobs

400-449

n/a

n/a

n/a

05900000- 59999999

1148 Personal Pendant

Zone Information

500-599

n/a

n/a

EM

04000000- 04999999

1154 Four-Zone Input Module

Zone Information

500-599

n/a

n/a

Any

08000000- 08999999

1158 Eight-Zone Input Module

Zone Information

500-599

n/a

n/a

Any

07000000- 07999999

1164 Smoke Detector with Sounder

Zone Information

500-599

n/a

n/a

FI

07000000- 07999999

1166 Smoke Ring

Zone Information

500-599

n/a

n/a

FI

06000000- 06999999

1168 CO/Smoke/Low Temp Combo Detector

Zone Information

Consecutive: 500-599

n/a

n/a

FI + CO + SV

07000000- 07999999

1183 Heat Detector

Zone Information

500-98

n/a

n/a

FI

06000000- 06999999

9000 Series Thinline Keypad

Device Setup

1-8

KPD or DOOR

WLS

n/a

14500000- 14999999

9800 Graphic Touchscreen Keypad

Device Setup

1-8

KPD or DOOR

WLS

n/a

14500000- 14999999