Entre
For connection to Entré, configure the following settings as needed:
Entré Connection: Select the connection type.
Entré IPv6: Select this option to enable IPv6.
Entré Incoming TCP Port: Enter the port number for the incoming Entré connection. The port identifies the port used to communicate with the Entré software. Default is 2011.
Entré IP: Enter the Entré IP address where the panel sends network messages. Default is 0.0.0.0.
Entré IPv6 Address: Enter the Entré IPv6 address where the panel sends network messages. Default is 0:0:0:0:0:0:0:0.
Entré Outbound TCP Port: Enter the port number for the outbound Entré connection. The port identifies the port used to communicate messages to the Entré software. Default is 2001.
Entré Backup Connection: Select a backup connection type. Entré Backup IP: Enter the backup Entré IP address where the panel sends network messages. Default is 0.0.0.0.
Entré Backup IPv6: Enter the backup Entré IPv6 address where the panel sends network messages. Default is 0:0:0:0:0:0:0:0.
Entré Backup TCP Port: Enter the backup port number for the outbound Entré connection. The port identifies the port used to communicate messages to the Entré software. Default is 2001.
Entré Arm/Disarm Reports: Sends arming, disarming and Late to Close events. Includes the area number, name and action, the user number and name, and the time and date the event occurred.
Entré Zone Reports: Sends changes in the status of active zones. Includes the zone number, name, type, the action (alarm, trouble, bypass, etc.), user number (if applicable), and area name. For a Walk Test, Verify and Fail messages are sent for each zone.
Entré User Command Reports: Sends user code changes, schedule changes, and door access denied events.
Entré Door Access Reports: Sends door access activity: door number, user number and name, and time and date the event occurred.
Entré Supervisory Reports: Sends system monitor reports, such as AC and battery, and system event reports. If this feature is enabled, the panel also sends Abort, Exit Error, Ambush, System Recently Armed, Alarm Bell Silenced, Unauthorized Entry, and Late to Close reports.
Entré Check-In Minutes: Select the rate at which check-in messages are sent over the Entré connection. Select 0 (zero) to disable check in messages. Range is 0, 3-240 minutes. Default is 0.
Entré Passphrase: To enable encryption, enter the alphanumeric Entré passphrase. If you leave the passphrase blank, the panel communicates with Entré, but the data is not encrypted. Default is blank.