Integrator Path
For connection to an integrator path, configure the following settings as needed:
Connection: Select the connection type. Incoming TCP Port: Enter the port number for the incoming connection. The port identifies the port used to communicate with the integrator software. Default is 2011.
Integrator IP: Enter the IP address where the panel sends network messages. Default is 0.0.0.0.
Outbound TCP Port: Enter the port number for the outbound integrator connection. The port identifies the port used to communicate messages to the integrator. Default is 2001.
Backup Connection: Select a backup connection type.
Backup IP: Enter the backup IP address where the panel sends network messages. Default is 0.0.0.0.
Backup TCP Port: Enter the backup port number for the outbound connection. The port identifies the port used to communicate messages to the software. Default is 2001.
Arm/Disarm Reports: Sends arming, disarming and Late to Close events. Includes the area number, name and action, the user number and name, and the time and date the event occurred.
Zone Reports: Sends changes in the status of active zones. Includes the zone number, name, type, the action (alarm, trouble, bypass, etc.), user number (if applicable), and area name. For a Walk Test, Verify and Fail messages are sent for each zone.
User Cmd Reports: Sends user code changes, schedule changes, and door access denied events.
Door Access Reports: Sends door access activity: door number, user number and name, and time and date the event occurred.
Supervisory Reports: Sends system monitor reports, such as AC and battery, and system event reports. If this feature is enabled, the panel also sends Abort, Exit Error, Ambush, System Recently Armed, Alarm Bell Silenced, Unauthorized Entry, and Late to Close reports.
Check-In Minutes: Select the rate at which check-in messages are sent over the connection. Select 0 (zero) to disable check in messages. Range is 0, 3-240 minutes. Default is 0.
Passphrase: To enable encryption, enter the alphanumeric passphrase. If you leave the passphrase blank, the panel communicates with the integrator, but the data is not encrypted. Default is blank.