When programming devices, consult the Quick Programming Reference as needed. To add a device, complete the following steps:
-
Go to Program > Device Setup > Path and select New.
-
In Device Number, enter the device's number:
-
The range for keypad, fire, and expander devices is 1-16 for XR550 panels and 1-8 for all other panels.
-
The range for doors is 1-16 and 501-961 for XR550 panels and 1-8 for all other panels.
-
The valid V-Plex device numbers are 501, 601, 701, 801, and 901. On XR150 panels, device 501 is reserved for a V-Plex device.
-
The valid range for 1100T is 2-16 for XR Series panels or 2-8 for all other compatible panels.
-
The valid range for a XR panel integration is 1-16.
-
-
In Name, enter a name for the device.
-
In Device Type, select one of the following types:
-
Door (DOOR)
-
Fire (FI)
-
Keypad (KPD)
-
Zone Expander (EXP)
-
1100T Wireless Translator (TLR)
-
Vplex PL-500 (VPX)
-
Secondary XR panel (PNL)
-
Camera (CAM)
-
-
In Device Communication Type, select Keypad Bus, AX-Bus, Network, or Wireless.
-
For wireless devices, enter the device Serial Number and select a Supervision Time.
-
For 1100T Wireless Translators, select an 1100T Frequency: o HWL (345 MHz) (Honeywell 5800) o 2GIG (345 MHz) (2GIG) o INT (319.5 MHz) (Interlogix) o DSC (433 MHz) (DSC)
-
Configure additional options as needed.
-
If necessary, enter a description for the device installation.
-
To configure 734 options for doors, go to the 734 Options tab. To configure card formats, select Card Formats.
-
Select Apply. Repeat steps 1-10 to add more devices as needed.
-
Select OK.