The following table columns are arranged to follow the typical panel programming order and values required for each item. For example, you should first program a wireless keypad in Device Setup, where you give it a device number, select a device type, select a device communication type, then enter the wireless serial number before programming other options. For additional installation requirements and programming options, refer to the model's installation guide.

  • Models: The accessory item's model number and name, linked to its installation guide.

  • Program In: The menu where you program the accessory: Device Setup, Zone Information, Output Information, or Key Fobs.

  • Device, Zone, or Output Number: The range of numbers for the accessory, depending on where it is programmed. See above. Keep in mind that although any device can be programmed as device 1 in the panel, that address should be reserved for the primary system keypad in most cases.

  • Device Type: If the accessory is programmed in Device Setup, this lists possible device types.

  • Device Communication Type: If the accessory is programmed in Device Setup, this lists possible communication types.

  • Zone Type: If the accessory is programmed in Zone Information, this lists possible zone types.

  • Wireless SN Range: For a wireless device, the typical serial number range of its class.

Models

Program In

XT75 Device, Zone, or Output Number

Device Type

Device Communication Type

Zone Type

Wireless SN Range

630F Fire Keypad

Device Setup

1-16

FI

n/a

n/a

n/a

7830F Graphic Remote Annunciator

Device Setup

1-16

FI

n/a

n/a

n/a

714/715 Zone Expansion Module

Device Setup

1-16

EXP

n/a

n/a

n/a

714-8/714-16 and 714-16/715-16 Zone Expansion Modules

Device Setup

1-16

EXP

n/a

n/a

n/a

1100R Repeater

Zone Information

Consecutive if more than one per panel: 500-599

AUX1

n/a

AUX1

13000000-13999999

1100T Wireless Translator

Device Setup

2-16

1100T

n/a

n/a

13000000-13999999

1100T Wireless Translator

Zone Information

500-599

n/a

n/a

Any

Non-DMP SN

1103 Universal Transmitter

Zone Information

Consecutive: 500-599

n/a

n/a

Any

01000000- 01999999

1164 Smoke Detector with Sounder

Zone Information

500-599

n/a

n/a

FI

07000000- 07999999

1166 Smoke Ring

Zone Information

500-599

n/a

n/a

FI

06000000- 06999999

1168 CO/Smoke/Low Temp Combo Detector

Zone Information

Consecutive: 500-599

n/a

n/a

FI + CO + SV

07000000- 07999999

1183 Heat Detector

Zone Information

500-599

n/a

n/a

FI

06000000- 06999999

1184 Carbon Monoxide Detector

Zone Information

500-599

n/a

n/a

CO

06000000- 06999999